CM2

/CM2
CM2 2016-10-24T12:19:42+00:00

CM2_top

BASEMENT – Perimetral frame carried out with galvanized metallic section bars 2 mm thick. joined by welding. External side painted with light colour. Transversal beams made with galvanized section bars “Omega” type 2 mm thick., welded to the perimetral frame. Fireproofed wood-chip under-floor panel, 18 mm thick, with PVC sheet floor surface, fire reaction Class 1. Galvanized U-profiles are welded under the base for movement by forklift truck or other suitable vehicles.

CM2_3d

CORNER COLUMNS – Carried out with galvanized section bars 2 mm thick. These connect the basement to the roof frame and fix the ends of the wall panels in place. They are fixed to the base corners and roof with galvanised bolts. External side (in sight) painted with light colour.

ROOF FRAME – Carried out with perimetral galvanized steel section bars 2 mm thick External side (in sight) painted with light colour.

EXTERNAL WALLS – Carried out with prepainted galvanized embossed sheet 0,5 mm thick. light colour. Insulation with expanded polyurethane 50 mm thick. selfextinguishing according to ASTM 1692/74 standardization, fire reaction Class 0-2 for the sandwich panel.

CM2_I_01

ROOF – Carried out with sandwich panel 30 mm thick. + ribs (40 mm), external and internal galvanized sheet 0,5 mm thick. prepainted light colour. Insulation with expanded polyurethane 50 mm thick. selfextinguishing according to ASTM 1692/74 standardization, fire reaction Class 0-2 for the sandwich panel. Further flat covering with galvanized ribbed sheet 0,5 mm thick. Downspout 50 mm diam. hidden into the four corners. Outrigger of gutter excluded.

DOORS AND WINDOWS – Doors and windows carried out with extruded section bar aluminium white colour. External door size cm. 100×206 half glazed, complete with lock, handles and protection bars; sliding window size cm 100×110 with single glass and external protection bars

ELECTRIC SYSTEM – Power supply 220V 1 phase 50 Hz. main board composed by bipolar differential magnetothermal switch and bipolar magnetothermal switches for every feeding lines; roof lamps 2x36W complete with switch; external lamp 60W complete with switch; sockets 10/16 A complete with wall box; external wall box for electric connection.

CM2_I_02